GESA样本分体水源热泵
来源:化拓教育网
GESA分体式水源热泵RTWB型216kW~745kW50Hz目录产品特性...................................................................3型号说明...................................................................4系统原理图...............................................................5技术参数表...............................................................6变工况性能参数表.....................................................7性能修正系数............................................................8热水盘管参数............................................................9机组尺寸图室外机.................................................10机组尺寸图室内机.................................................11安装注意事项..........................................................12电气接线图.............................................................132产品特性概述GESA分体式水源热泵是Trane最新开发的新一代高效节能型产品。机组安装于室内可以减小对环境的影响;同时可根据面积的变化灵活增加机组数量,有效提高用户的资金利用状况;室内/外机分压缩机开安装,减少室内噪音,室内吊顶安装空间占用少,美观大方,广泛地应用于别墅、商场、宾馆、医院以及商务楼宇等场所。靠;各机组运行相对独立,个别机组的故障不会影响整个系统和其它机组的正常运行。分体式结构机组采用分体式结构,压缩机和水/冷媒换热器在外机中配以优质的吸音材料,同时内机所用电机、风机均为知名品牌,大大降低了机组的噪音。室内噪音小,吊顶安装空间占用少,安装美观大方。系统优点高效节能与集中式空调系统相比,水源热泵系统一大优势在于在部分负荷时只需启动机组本身和循环水,不用频繁启停锅炉和冷却塔系统,这样大大节省了能源;而在套管式换热器过渡季节,空调系统中各机组同时供冷和供暖的情况下,节能效果更加明显。运行范围宽广采用节流阀精确调节冷媒流量使机组的运行更加稳定,水温运行范围从13˚C到41˚C。设计独特同心套管式冷凝盘管,热交换效率高,同时可有效减少污垢和压力损失。应用灵活两管制系统实现四管制系统功能,可同时满足各区域单独制冷/制热需求。节约初投资无需设立专门的冷冻机房和大的通风管道,没有大的锅炉房和冷冻水系统,因此安装和投资费用大大减少。精确控制采用先进的微电脑控制配以大屏幕液晶温控器,美观大方;多种工作模式可选,室内风机速度可调;同时随机可选配遥控器,满足客户对舒适便捷的要求;可接驳集中控制器,实现全系统智能化高效运行。单独计量单户单表,每个用户可将自身的电表系统和空调系统连接,单独计费。大楼管液晶温控器理人员、物业部门、业主再也无须为空调费用的结算发愁,真正实现公正、公平。可靠性高水温波动范围小,保证机组运行高效可3型号说明室外机GESA0096H5AA1第1,2位第3位第4位第5,6,7位234S=分体式5678910H=热泵C=单冷1112GE=水源热泵A=发展序号名义冷量009012018024036048060第9位冷媒循环第10位第11位第12位5=螺纹连接0=焊接连接设计更改代码A=首次设计产品序列号A=首次设计第8位电源类型6=220-240V/50Hz/1PH9=380-415V/50Hz/3PH室内机MWD509SAWLANNNA1第1位第2位23456789101112131415K=配3.6kW电加热器(限36)L=配4.6kW电加热器(限36,48,60)M=配6.9kW电加热器(限48,60,380V/3PH/50Hz)P=配9.2kW电加热器(限48,60,380V/3PH/50Hz)热水盘管N=无(标准配置)S=单排热水盘管D=双排热水盘管回风箱N=无B=后回风箱D=下回风箱过滤网N=无F=过滤网设计更改A=首次设计变化M=Trane分体系列C=单冷W=热泵第3位D=管道机第4位5=螺纹连接0=焊接连接第5,6位名义冷量09,12,18,24,36,48,60第7位设计序列号S=分体式第8位电源类型A=220/50Hz/1PH第9位控制器W=线控(标准配置)R=线控+遥控第10位盘管接管L=左接管(标准配置)R=右接管第11位电加热A=不配电加热(标准配置)C=配1.0kW电加热器(限09)D=配1.4kW电加热器(限12)F=配1.8kW电加热器(限18)H=配2.8kW电加热器(限24,36)第12位第13位第14位第15位注:1.回风箱对于509~524为选配,036,048,060为标准配置2.509~524若选择过滤网,必须选择回风箱4系统原理图典型的水源热泵系统图水泵板式换热器锅炉水-水热泵分体式水源热泵整体式水源热泵注:本系统图仅为示意图,水环路各阀件、组件的选择请参考设计手册5技术参数表分体式水源热泵GESA名义工况参数表机组型号室外机室内机Kcal/Hr制冷能力Btu/hkWKcal/Hr制热能力Btu/hkW电源风量整机功率整机电流EER室内室外V/PH/HzV/PH/Hzm3/h制冷(kW)制热(kW)运行电流(A)W/W机外静压(pa)室内机6500.800.953.763.638900.940.964.383.9920220/1/5012801.461.686.83.9714502.002.449.123.603020002.823.486.53.83GESA009GESA012GESA018GESA024GESA036GESA048GESA060MWD060SA144485712016.8193507650022.5MWD509SAMWD512SAMWD518SAMWD524SAMWD536SAMWD048SA249498602.93354132603.93225127503.753870153004.54988197205.86278248207.36192244807.28084319609.4220/1/50380/3/5029004.144.828.93.74801330x825x36558涡旋式1同轴套管式0.6715.00.9024.0456x456x4203335411.2913.01.5822.12.2830.03.3333.03.7071.229604.525.359.63.7292883672010.8125564964014.6133305270015.5189207480022外形尺寸(WxDxH)mm679x566x265929x566x2651064x566x2651349x566x2651130x715x315运行重量(Kg)压缩机形式数量形式2025转子式273347室外机冷凝器水流量(m3/h)水压降(kpa)外形尺寸(WxDxH)mm运行重量(Kg)656x606x48058R2270656x606x5509698制冷剂冷媒接管尺寸进出水管尺寸冷凝水管尺寸种类充注量(Kg)气管(inch)液管(inch)inchinch0.783/8\"1/4\"1.081/2\"1.445/8\"2.102.503/4\"3/8\"4.221-1/8\"4.373/4\"3/4\"测试标准:依据GB/T19409-2003名义制冷工况:室内进风干湿球温度27˚C/19˚C;进出水温度30˚C/35˚C名义制热工况:室内进风干湿球温度20˚C/15˚C;进水温度20˚C以上参数会因产品的改进而更改,恕不另行通知,请以铭牌参数为准6变工况性能参数表变工况性能参数表型号名义风量m3/h名义水流量m3/h制冷(进风27/19˚C,DB/WB)进水温度˚C2024GESA0096500.673035402024GESA0128900.903035402024GESA01812801.293035402024GESA02414501.583035402024GESA03620002.283035402024GESA04829003.333035402024GESA06029603.70303540制冷量(kW)3.203.102.902.702.504.183.983.753.573.356.556.165.805.515.108.007.707.206.706.2011.8811.3410.8010.269.5016.4315.9615.5014.7214.1017.5017.2016.8016.5016.107制热(进风20˚C,DB)进水温度˚C1315202430131520243013152024301315202430131520243013152024301315202430制热量(kW)3.603.703.904.104.403.904.304.504.704.906.416.927.307.818.258.208.809.409.9010.6012.4013.4014.6015.6016.7019.8020.9022.0022.6723.3220.1021.3022.5023.4024.50功耗(kW)0.930.940.950.960.970.910.930.960.991.021.521.591.681.761.812.102.272.442.542.653.233.353.483.603.734.554.674.824.945.085.115.225.355.475.56功耗(kW)0.680.740.800.891.020.760.840.941.031.151.261.331.461.571.681.741.852.002.152.302.452.592.822.983.173.513.724.144.464.923.824.154.524.915.35性能修正系数风量-冷热量修正系数表风量变化80%85%90%95%100%110%115%120%制冷制热制冷量输入功率制热量输入功率0.970.980.990.9911.011.021.030.960.970.980.9911.021.031.040.970.980.990.9911.011.021.031.031.021.021.0110.980.980.97进风状态-冷热量修正系数表制冷进风湿球温度(˚C)101517192324总制冷量0.760.850.9411.121.18制冷输入功率0.920.950.9711.031.04/在下列制冷进风干球温度(˚C)时的显热量1921/24//27//32///1.21制热进风干球温度(˚C)121517202327总制热量制热输入功率1.050.931.030.951.020.98110.780.860.50.710.921.130.370.570.79////10.520.730.94/0.50.720.981.020.961.06管道长度型号5m0MWD/MCD509SA1.00MWD/MCD512SA1.00MWD/MCD518SA1.00MWD/MCD524SA1.00MWD/MCD536SA1.00MWD/MCD048SA1.00MWD/MCD060SA1.010m00.98500.98100.97900.9760.150.9730.150.9700.150.97115m0.120.9400.120.9380.120.9370.120.9350.30.9300.30.9310.30.928需补充冷媒量(R22)kg制冷/制热量校正因子20m----0.180.9050.180.9020.450.8940.450.8960.450.89225m--------0.60.8800.60.8760.60.87730m--------0.750.8740.750.8730.750.87335m----------0.90.8580.90.85840m----------1.050.851.050.849注:上表中不同型号机组对应的每栏上半部分代表在不同冷媒管道长度时需充注的冷媒量,下半部分代表在不同冷媒管道长度时机组的制冷/制热量校正因子。8热水盘管参数单排热水盘管进水/出水温度(˚C)机组型号MCD/MWD509SAMCD/MWD512SAMCD/MWD518SAMCD/MWD524SAMCD/MWD536SAMCD/MWD048/060SA90/7080/6060/5045/40制热量(kW)热水流量(l/s)制热量(kW)热水流量(l/s)制热量(kW)热水流量(l/s)制热量(kW)热水流量(l/s)5.298.429.6712.8718.4927.520.0630.100.1160.1540.2210.3294.236.827.5810.2414.9922.460.0510.0820.0910.1230.1790.2693.064.895.567.4310.7416.020.0730.1170.1330.180.2580.3842.03.183.674.876.9810.390.0960.1530.1760.2340.3350.498双排热水盘管进水/出水温度(˚C)机组型号MCD/MWD509SAMCD/MWD512SAMCD/MWD518SAMCD/MWD524SAMCD/MWD536SAMCD/MWD048/060SA90/7080/6060/5045/40制热量(kW)热水流量(l/s)制热量(kW)热水流量(l/s)制热量(kW)热水流量(l/s)制热量(kW)热水流量(l/s)7.4911.9113.8418.3526.4839.480.0890.1420.1650.2190.320.476.039.6910.5514.3421.6432.430.0720.1160.1260.1740.260.394.336.97.8510.5515.3522.920.1040.1650.1880.2530.370.552.874.465.176.899.9214.780.1350.2140.2480.7690.480.71注:以上数据是在名义风量下,室内温度为20˚C时测得。建议进水温度不超过80˚C。附件压力损失表(Pa)机组型号MCD/MWD509SAMCD/MWD512SAMCD/MWD518SAMCD/MWD524SAMCD/MWD536SAMCD/MWD048/060SA单排热水盘管-20%45661015名义风量78891520-20%7911111827双排热水盘管名义风量1214141627369机组尺寸图室外机单位:mmGESA009-018456421.6GESA024-036656621.64-ø104565235534-ø10出水口3/4\"进水口3/4\"液管接头420气管接头出水口3/4\"进水口3/4\"液管接头480901341361347811010577525.8141.5135155110气管接头726.6GESA048-060656621.64-ø10出水口3/4\"进水口3/4\"液管接头550110气管接头13477141.540135155426.660667370310606673703机组尺寸图室内机MW(C)D509/512/518/524SA电气盒过滤网(可选)BE回风箱(可选)详图A14ø18吊装孔(4个),见详图3/8\"冷媒入口管热水盘管(可选)ø11出水管接头内螺纹ZG3/4\"后回风口(可选)125124进水管接头下回风口(可选)610(下回风)595(后回风)出水嘴20内螺纹ZG3/4\"ABC42220260217217积水盘型号MCD/MWD509MCD/MWD512MCD/MWD518MCD/MWD524外形尺寸A4807308651150B5307809151200C67992910641349E4907408751160MWD536/048/060SA尺寸ABCDEMAABB冷媒入口管径冷媒出口管径对接方式机型3/8\"3/4\"螺母MWD536SA1130300715420982159482483/8\"11/8\"焊接MWD048/060SA133035082553011823651148298注:标注尺寸单位为毫米。119344122265608排水接头(外螺纹ZG3/4\")16282755465665/8\"冷媒出口管安装注意事项室内机安装注意事项1.便于气流组织分配•不能对人直吹。•机组制冷或制热时室内机组的送风和回风必须能使房间大部分空气与空调内机形成良好的热交换。•当大厅的天花板过高时,制热时热气流将无法到达地面,人员取暖效果差,且热气停留在上部,将会关闭主机辅助电加热或压缩机运行。•建议采用增加出风口空气流速,改变出风口格栅的方向来保证热气流能到达地面。•注意安装空间,尽量避免机组在较小的空间内引起共振声。少弯曲和上下位移。2.水管之间的连接件采用柔性连接,可有效减少震动,防止管道震松漏水。3.检修阀门。在维修保养时可关闭,使机组和管道分离。4.保持系统足够的水压以保证水流速。5.开式系统中需要在水泵前安装水过滤器以防止杂质进取套管式换热器。6.尽可能对水管进行绝热保护以免冷凝水的产生。3.注意冷凝水管的高低,以防漏水室外机安装注意事项1.室外机安装位置应考虑维修方便,保证足够的维修空间。2.对于一些湿度较大位置应尽量避免以免对机组电气元件造成损害。3.应充分考虑噪音因素,可在走廊等不敏感区域安装。4.安装时应考虑冷媒管连接长度符合机组实际能力,避免压降产生回油和制冷能力不足等问题。冷媒管接管长度要求当冷媒管太长时,由于弯头数增加阻力也会相应增加,系统的冷量和可靠性均会下降。因此要充分考虑最短的连接管长确保机组可靠运行。2.噪音•不要把内机安装在人休息的顶部区域。水环路的安装注意事项1.所有水管系统的安装在设计时尽量减A.室外机在低位置时液体止回环B.室外机在高位置时室内机室外机最大高度最大高度集油器(每隔6米设置1个)图表符号:液管室外机12气管室内机电气接线图009-024单冷(热泵)+单相电加热室内侧MCD509/512/518/524SA(单冷)MWD509/512/518/524SA(热泵)220V~/50HZNL室外侧GESA009/012/018/0246C(单冷)GESA009/012/018/0246H(热泵)该线现场连接,由工厂提供(7米)NLYLYOV(O端子之间连线只限热泵机组)OVVHPLPCTRoomLPFSFS盘管温度房间温度电脑主板FSOFS进水温度出水温度CNTRCNTREWLW室内回风探头接线座高压开关水流开关红色兰色出水温度探头进水温度探头低压开关线控器兰色黑色遥控器电加热盘管温度探头空中对接端子压缩机黄/绿色火线零线水阀现场接线工厂接线备注:1.除了室外温度探头连接线和有线遥控接收器线由本公司提供以外,电源线、内外机连接线由用户自行提供,线径请参考随机资料。2.控制器有两种配置1)有线控制面板2)有线控制面板+手持式无线遥控控制器白色棕色黑色黄色电源线及内外机连接线线径规格表内机外机热泵/单冷热泵+电加热LNYOVHPFSMC/WD509SAGESA0091.52111.51111MC/WD512SAGESA0121.52.51.51.51.51111MC/WD518SAGESA0182.52.52.52.52.51111MC/WD524SAGESA0242.542.52.52.51111内机电源线内外机连接线mm2mm2mm2mm2mm2mm2mm2mm2mm2备注:GESA009-024,外机电源由内机引入13电气接线图036/048/060单冷(热泵)+单相电加热MCD536/048/060SA(单冷)220V~/50HZNL380V~/50HZNWVU室内侧MWD536/048/060SA(热泵)附件:辅助电加热器室外侧GESA036/048/0609H(热泵)UVWNGESA036/048/0609C(单冷)该线现场连接,由工厂提供(7米)HNLYLYOV(O端子之间连线只限热泵机组)OVVHPLPCTRoomLPFSFS盘管温度房间温度电脑主板FSOFS进水温度CNTREW出水温度CNTRLW室内回风探头接线座高压开关水流开关红色兰色出水温度探头进水温度探头低压开关线控器兰色黑色遥控器电加热盘管温度探头空中对接端子压缩机黄/绿色火线零线水阀现场接线工厂接线备注:1.除了室外温度探头连接线和有线遥控接收器线由本公司提供以外,电源线、内外机连接线由用户自行提供,线径请参考随机资料。2.控制器有两种配置1)有线控制面板2)有线控制面板+手持式无线遥控控制器白色棕色黑色黄色电源线及内外机连接线线径规格表内机外机热泵/单冷热泵+单相电加热LYOVLPFSMC/WD536SAGESA03612.52.51.51.51111MC/WD048SAGESA0481.542.51.51.51111MC/WD060SAGESA0601.542.51.51.51111内机电源线外机电源线内外机连接线mm2mm2mm2mm2mm2mm2mm2mm2mm214电气接线图048/060单冷(热泵)+三相电加热室内侧MCD048/060SA(单冷)MWD048/060SA(热泵)附件:辅助电加热器380V~/50HZUVWN220V~/50HZNL380V~/50HZNWVU室外侧UVWNGESA048/0609C(单冷)GESA048/0609H(热泵)该线现场连接,由工厂提供(7米)HNLYLYOV(O端子之间连线只限热泵机组)OVVHPLPCTRoomLPFSFS盘管温度房间温度电脑主板FSOFS进水温度出水温度CNTRCNTREWLW室内回风探头接线座高压开关水流开关红色兰色出水温度探头进水温度探头低压开关线控器兰色黑色遥控器电加热盘管温度探头空中对接端子压缩机黄/绿色火线零线水阀现场接线工厂接线白色棕色黑色黄色备注:1.除了室外温度探头连接线和有线遥控接收器线由本公司提供以外,电源线、内外机连接线由用户自行提供,线径请参考随机资料。2.控制器有两种配置1)有线控制面板2)有线控制面板+手持式无线遥控控制器电源线及内外机连接线线径规格表内机外机热泵/单冷内机电源线热泵+单相电加热三相电加热(单独配电)外机电源线LYO内外机连接线VLPFSMC/WD048SAGESA0481.542.52.51.51.51111MC/WD060SAGESA0601.542.52.51.51.51111mm2mm2mm2mm2mm2mm2mm2mm2mm2mm2备注:GESA048、060选用的电加热为三相时要单独配电,接线方式与单相电加热不同。15LiteratureOrderNumberWSHP-PRC015-ZH(June2005)FileNumberSupersedesTraneAbusinessofAmericanStandardCompanieswww.trane.comPL-UN-000-WSHP-PRC015-ZH-0605March2005TaiCangStockinglocationFormoreinformation,contactyourlocaldistrictoffice特灵公司产品不断改进求新,本文件数据如有变动,恕不另行通知。
因篇幅问题不能全部显示,请点此查看更多更全内容