Catalog 1308242Issued 3-03 (PDF Rev. 10-07)AGASTAT7000 seriesIndustrial ElectropneumaticTiming RelayFile E15631File LR29186Note:7032 types and certain models with accessories are not agency approved.Users should thoroughly review the technical data before selecting a productpart number. It is recommended that users also seek out the pertinentapprovals files of the agencies/laboratories and review them to confirm theproduct meets the requirements for a given application.Consult factory for ordering information.

Design Features

•Available in on-delay, true off-delay, and on/off-delay.

•Timing from 0.1 seconds to 60 minutes, in linear increments.

•Oversize time-calibrated adjustment knobs, serrated with high-resolutionmarkings visible from all angles makes the timer easy to set timers.•Inherent transient immunity.

•Standard voltages from 6-550VAC and 12-550VDC (special voltages available.)•Available in 2-pole or 4-pole models.

•Numerous enclosure options: explosion proof, dust tight, watertight,hermetically-sealed, NEMA 1.

•Auxiliary timed and instantaneous switches can be added for greater switchingflexibility.

•Many mounting options: Surface mount, Panel mount, Octal plug-in mounting.•Options: quick-connect terminals, dial stops, and transient protection module.•Easy-to-reach screw terminals, all on the face of the unit, clearly identified.•Modular assembly - timing head, coil assembly and switchblock are allindividual modules, withswitches field-replaceable.

On-delay model 7012 (delay on pickup)

Applying continuous voltage to the coil(L1-L2) starts a time delay lasting forthe preset time. During this period thenormally closed contacts (3-5 and 4-6)remain closed. At the end of the delayperiod the normally closed contactsbreak and the normally open contacts(1-5 and 2-6) make. The contacts re-main in this transferred position untilthe coil is deenergized, at which timethe switch instantaneously returns toits original position.

De-energizing the coil, either duringor after the delay period, will recyclethe unit within 50 msec.

It will then provide a full delay periodupon re-energization, regardless ofhow often the coil voltage is interrupt-ed before the unit has been permittedto \"time-out\" to its full delay setting.

Design & Construction

There are three main components of Series 7000 Timing Relays:

Calibrated Timing Headuses no needle valve, recirculates air undercontrolled pressure through a variable orifice to provide linearly adjustabletiming. Patented design provides instant recycling, easy adjustment and longservice life under severe operating conditions.

Precision-Wound Potted Coilmodule supplies the initial motive forcewith minimum current drain. Total sealing without external leads eliminatesmoisture problems, gives maximum insulation value.

Snap-Action Switch Assembly- custom-designed over-centermechanism provides greater contact pressure up to transfer time forpositive, no flutter action. Standard switches are DPDT arrangement, withflexible beryllium copper blades and silver-cadmium oxide contacts. Special\"timing-duty\" design assures positive wiping action, sustained contact pres-sure and greater heat dissipation during long delay periods.

Each of these subassemblies forms a self-contained module which isthen assembled at the factory with the other two to afford a wide choice ofoperating types, coil voltages, and timing ranges.

The squared design with front terminals and rear mounting permits thegrouping of Series 7000 units side-by-side in minimum panel space.Auxiliary switches may be added in the base of the unit, without affectingthe overall width or depth.

Off-delay model 7022 (delay on dropout)

Applying voltage to the coil (for atleast 50 msec) will instantaneouslytransfer the switch, breaking the nor-mally closed contacts (1-5 and 2-6),and making the normally opencontacts (3-5 and 4-6). Contactsremain in this transferred position aslong as the coil is energized. Thetime delay begins immediately uponde-energization. At the end of the de-lay period the switch returns to itsnormal position.

Re-energizing the coil during thedelay period will immediately returnthe timing mechanism to a pointwhere it will provide a full delayperiod upon subsequent de-energization. The switch remains inthe transferred position.

Operation

Two basic operating types are available.

“On-Delay” models provide a delay period on energization, at the end ofwhich the switch transfers the load from one set of contacts to another. De-energizing the unit during the delay period immediately recycles the unit,readying it for another full delay period on re-energization.

In \"Off-Delay\" models the switch transfers the load immediately uponenergization, and the delay period does not begin until the unit is de-energized. At the end of the delay period the switch returns to its original po-sition. Re-energizing the unit during the delay period immediately resets thetiming, readying it for another full delay period on de-energization. No poweris required during the timing period.

In addition to these basic operating types, \"Double-Head\" models offersequential delays on pull-in and drop-out in one unit. With the addition ofauxiliary switches the basic models provide two-step timing, pulse actuationfor interlock circuits, or added circuit capacity.

NOTE: Seismic & radiation tested E7000 models are available.

Consult factory for detailed information.

Dimensions are shown for

Dimensions are in inches over(millimeters) unless otherwisespecified.

To increase the versatility of the basic timer models, auxiliary switches maybe added to either on-delay or off-delay types. They switch additional circuits,provide two-step timing action, or furnish electrical interlock for sustained coilenergization from a momentary impulse, depending on the type selected andits adjustment. Because of their simple attachment and adjustment features,they can be installed at the factory or in the field, by any competent mechanic.All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480VAC. A maximum of one Code T or two Code L auxiliary switches may beadded to each relay. The L or LL switch is available with on-delay relays only.The T switch is available with both the on-delay and off-delay relays.Auxiliary Switch Options for On-DelayInstant Transfer (Auxiliary Switch Code L, maximum of 2 per relay.)

1.Energizing coil begins time delay and transfers auxiliary switch.2.Main switch transfers after total preset delay.3.De-energizing coil resets both switches instantly.Auxiliary switch is nonadjustable.

Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.)

Specifications and availabilitysubject to change.

www.tycoelectronics.comTechnical support:

Refer to inside back cover.

1248reference purposes only.

http://oneic.com/

Catalog 1308242Issued 3-03 (PDF Rev. 10-07)AGASTATAuxiliary switch optionsTo increase the versatility of the basic timer models, auxiliary switches maybe added to either on-delay or off-delay types. They switch additional circuits,provide two-step timing action, or furnish electrical interlock for sustained coilenergization from a momentary impulse, depending on the type selected andits adjustment. Because of their simple attachment and adjustment features,they can be installed at the factory or in the field, by any competent mechanic.All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480 VAC.A maximum of one Code T or two Code L auxiliary switches may be added toeach relay. The L or LL switch is available with on-delay relays only. The Tswitch is available with both the on-delay and off-delay relays.Auxiliary Switch Options for On-DelayInstant Transfer (Auxiliary Switch Code L, maximum of 2 per relay.)1.Energizing coil begins time delay and transfers auxiliary switch.2.Main switch transfers after total preset delay.3.De-energizing coil resets both switches instantly.Auxiliary switch is nonadjustable.

Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.)1.Energizing coil begins time delay.

2.After first delay auxiliary switch transfers.3.Main switch transfers after total preset delay.

4.De-energizing coil resets both switches instantly. First delay isindependently adjustable, up to 30% of overall delay. (Recommended maximum 100 seconds.)Auxiliary Switch Options for Off-DelayIn these models the same auxiliary switch provides either two-step timing orinstant transfer action, depending on the adjustment of the actuator.

Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.)1.Energizing coil transfers main and auxiliary switches instantly.2.De-energizing coil begins time delay.3.After first delay auxiliary switch transfers.

4.Main switch transfers after total preset delay. First delay is independentlyadjustable, up to 30% of overall delay. (Recommended maximum 100 sec-onds.)

Instant Transfer (Auxiliary Switch Code L, maximum of 1 per relay.)1.Energizing coil transfers main and auxiliary switches instantly.2.De-energizing coil resets auxiliary switch and begins time delay.3.Main switch transfers after total preset delay.

Auxiliary switch is factory adjusted to give instant transfer operation, but maybe easily adjusted in the field to provide two-step timing.

On-delay, off-delay model 7032 (double head)

The Double Head model provides delayed switch transfer onenergization of its coil, followed by delayed resetting upon coil de-energization. Each delay period is independently adjustable.

In new circuit designs or the improvement of existing controls now

using two or more conventional timers, the Double Head unit offers distinctadvantages.

Its compact design saves precious panel space, while the simplifiedwiring reduces costly interconnection.

Four pole model 7014. 7024

With the addition of an extra switch block at the bottom of the basic unit,this version of the Series 7000 offers four pole switch capacity with simul-taneoustiming or two-step timing. The two-step operation is achieved byfactory adjustment to your specifications.

For two-step operation, a maximum timing ratio between upper andlower switches of 3:2 is recommended. Once adjusted at the factory, thisratio remains constant regardless of changes in dial settings. (Ex: If upperswitch transfer is set on dial at 60 sec., minimum time on lower switchshould be 40 sec.)

This Series 7000 unit offers many of the performance features found inbasic models - voltage ranges, timing and switch capacities are virtually iden-tical.

Four pole models add approximately 1-1/4\" to the maximum height of thebasic model, approximately 1/8\" to the depth. They are designed for verticaloperation only.

Surge/transient protection option

Features

•Protect electronic control circuitsfrom voltage transients generatedby the timer coil.

•Fast response to the rapidly risingback E.M.F.

•High performance clamping voltagecharacteristics.

•UL recognized, (except varistor andcoil together).

•Timer NOT polarity sensitive.

The Surge/Transient Protection Option protects electronic control circuits fromtransients and surges which are generated when the timer coil is activated.Built with a minimum of moving parts, the unit provides a fast response to rap-idly rising voltage transients. The accurate, precision-made device is not polari-ty sensitive and permits the user to initiate, delay, sequence and programequipment actions over a wide range of applications under the most severeoperating conditions.

It consists of a specially modified coil case, varistor, varistor cover, terminalextensions and cup washers so that normal terminations can be used. Thevaristor will not affect the operating characteristics of the 7000 Timer. Thevaristor has bilateral and symmetrical voltage and current characteristics andtherefore can be used in place of the back-to-back zener diodes. This charac-teristic also means that the coil will not be polarity sensitive.

Transient Suppressor

Option \"V\"

Dimensions are shown forreference purposes only.

Dimensions are in inches over(millimeters) unless otherwisespecified.

Specifications and availabilitysubject to change.

www.tycoelectronics.comTechnical support: 1249Refer to inside back cover.

http://oneic.com/

Catalog 1308242Issued 3-03 (PDF Rev. 10-07)AGASTATTiming Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified).

Operating Modes:

Model 7012/7014: On-delay (delay on pick-up).Model 7022/7024: Off-delay (delay on drop-out).Model 7032: On-delay, off-delay (double head).

Timing Adjustment:Timing is set by simply turning the dial to the desiredtime value. In the zone of approximately 25°separating the high and lowend of timing ranges A,D,E, and K, instantaneous operation (no time delay)will occur. All other ranges produce an infinite time delay when the dial isset in this zone.

Models 7014 and 7032 are available with letter-calibrated dials only. Theupper end of the time ranges in these models may be twice the valuesshown.

Linear Timing Ranges:Models 7012,Models 7014,

Code7022, 7024 7032A.1 to 1 Sec..2 to 2 Sec.B.5 to 5 Sec..7 to 7 Sec.C1.5 to 15 Sec2 to 20 Sec.D5 to 50 Sec.10 to 100 Sec.E20 to 200 Sec.30 to 300 Sec.F1 to 10 Min.1.5 to 15 Min.H3 to 30 Min.3 to 30 Min.I6 to 60 Min.Not Avail.J3 to 120 Cyc.Not Avail.K1 to 300 Sec.Not Avail.7012*, 7022, 7024:+5%7014*:+10%7032:+15%For delays greater than 200 seconds: 7012*, 7022, 7014*, 7024:+10%7032:+15%* The first time delay afforded by Model 7012 with H (3 to 30 min.) and I (6to 60 min.) time ranges or Model 7014 with H time range will be approx.15% longer than subsequent delays due to coil temperature rise.Reset Time:50 msec. (except model 7032)

Relay Release Time:50 msec. for on-delay models (7012/7014)Relay Operate Time:50 msec. for off-delay models (7022/7024)Operating Voltage Coil Data (for DPDT)CoilPart #7000

CodeLetterABCDEFGHIJK L

7010

MNOPQRSTUVWYZX

28482412512602505501632966220RatedVoltage12024048055024126208

Operating*VoltageRange@ 60Hz102-132204-2408-528468-60520.5-26.510.2-13.25.1-6.6178-229

Dual Voltage Coil (Combines A&B)Special AC Coils (L1, L2, etc.)22.4-30.838.4-52.819.2-26.4100-137.59.6-13.248-66200-275440-60512.8-17.625.8-35.276.8-105..8-6.6176-242

Special DC Coils (X1, X2, etc.)

RatedVoltage110220

OperatingVoltageRange@50Hz93.5-121187-242

Repeat Accuracy:

For delays of 200 seconds or less:

Minimum operating voltages are based on vertically mounted 7012 units.7012 horizontally mounted or 7022 vertically or horizontally mounted unitswill operate satisfactorily at minimum voltages approximately 5% lower thanthose listed.

AC units drop out at approximately 50% of rated voltage. DC units drop outat approximately 10% of rated voltage.

All units may be operated on intermittent duty cycles at voltages 10% abovethe listed maximums (intermittent duty - maximum 50% duty cycle and 30minutes \"on\" time.)

Surge/Transient Protection Option Characteristics (DC Timers Only)

Coil VoltageMax ExcessMax De-energizationNominal (DC)Energy Capacity (Joule)Transient Voltage12 V24 V28 V32 V48 V60 V96 V110 V125 V220 V250 V

0.4 J1.8 J1.8 J2.5 J3.57 J6 J10 J10 J10 J17 J17 J

48 V93 V93 V135 V145 V250 V340 V340 V340 V366 V366 V

Surge Life

Applied 100,000 times continuously with the interval of 10 seconds at roomtemperature. Below 68 VAC: 12A; Above 68 VAC: 35ATemperature Range

Operating: -22°F to +167°F (-30°C to + 75°C)Storage:-40°F to +167°F (-40°C to +75°C)

Output/Life Contact Ratings:Contact Capacity in Amps (Resistive Load)ContactMin. 100,000Min. 1,000,000VoltageOperationsOperations30 VDC15.07.0110 VDC1.00.5120 V 60Hz20.015.0240 V 60Hz20.015.0480 V 60Hz12.010.010 Amps Resistive, 240 VAC

1/4 Horsepower, 120 VAC/240VAC (per pole)15 Amps 30 VDC (per pole)

5 Amps, General Purpose, 600VAC (per pole)

Dielectric:Withstands 1500 volts RMS 60Hz between terminals andground. 1,000 volts RMS 60 Hz between non-connected terminals. Fordielectric specification on hermetically sealed models consult factory.Insulation Resistance:500 Megohms with 500VDC applied.

Temperature Range:Operating:-20°F to +165°F (-29°C to 74°C)

Storage:-67°F to +165°F (-55°C to 74°C)

Temperature Variation:Using a fixed time delay which was set andmeasured when the ambient temperature was 77°F (25°C), the maximumobserved shift in the average of three consecutive time delays was -20% at-20°F (-29°C) and +20% at 165°F (74°C).

Mounting/Terminals:Normal mounting of the basic unit is in a verticalposition, from the back of the panel. A front mounting bracket is alsosupplied with each basic unit, for installation from the front of the panel.All units are calibrated for vertical operation. Basic models (7012, 7022)may also be horizontally mounted, and will be adjusted accordingly whenAccessory Y1 is specified in your order.

Standard screw terminals (8-32 truss head screws supplied) are locatedon the front of the unit, with permanent schematic markings. Barrier

isolation is designed to accommodate spade or ring tongue terminals, withspacing to meet all industrial control specifications.

The basic Series 7000 may also be panel mounted with the addition of apanelmount kit that includes all necessary hardware and faceplate. Thisoffers the convenience of \"out-front\" adjustment, with large calibrated dialskirt knob. The faceplate and knob blend with advanced equipment andconsole designs, while the body of the unit and its wiring are protectedbehind the panel.

Other mounting options include plug-in styles and special configurationsto meet unusual installation requirements. Contact factory for details.Power Consumption: Approximately 8 watts power at rated voltage .Approximate Weights:

Models 7012, 7022 . . . . . . .2 lbs. 4 ozs.

7014, 7024 . . . . . . .2 lbs. 10 ozs.7032 . . . . . . . . . . . .3 lbs. 5 ozs.

Weight may vary slightly with coil voltage.

AC

127240108-140204-2

DC

*Four pole Models: Operational voltage range 90% to 110% for AC units;85% to 110% for DC units.See next column for more coil data.

1250reference purposes only.

Dimensions are shown for

http://oneic.com/

Dimensions are in inches over(millimeters) unless otherwisespecified.

Specifications and availabilitysubject to change.

www.tycoelectronics.comTechnical support:

Refer to inside back cover.

Catalog 1308242Issued 3-03 (PDF Rev. 10-07)AGASTATOutline Dimensions (Dimensions in inches).Models 7012, 7022

Models 7014, 7024

Model 7032

Panel mount Option \"X\"Surge/Transient Protection Option

http://oneic.com/

Dimensions are shown forreference purposes only.

Dimensions are in inches over(millimeters) unless otherwisespecified.

Specifications and availabilitysubject to change.

www.tycoelectronics.comTechnical support: 1251Refer to inside back cover.

Catalog 1308242Issued 3-03 (PDF Rev. 10-07)AGASTATOrdering InformationTypical Part No. ®1.Basic Series:70 = 7000 series electropneumatic timing relay2.Operation:1 = On-delay2 = Off-delay3.Contact Arrangement:2 = 2PDT (2 form C) 3 = On-delay, off-delay (double head)7012ADGZ**4 = 4PDT (4 form C)DC CoilsM = 28VDCN = 48VDCO = 24VDCP = 125VDCQ = 12VDCR = 60VDCS = 250VDCT = 550VDCU = 16VDCV = 32VDCW = 96VDCY = 6VDCZ = 220VDCX = Special DC coils (X1, X2, etc.)†Models 7014 & 7032For model 7032 specify separate timerange code for each head. Example: AB. Any two ranges may be selected.A = .2 to 2 sec.B = .7 to 7 sec.C = 2 to 20 sec.D = 10 to 100 sec.E = 30 to 300 sec.F = 1.5 to 15 min.H = 3 to 30 min.K = Explosion-proof Enclosure (note 1). L = Auxiliary Switch, instant transfer. 7012 only (notes 2 & 6).LL = Two Aux. Switches, instant transfer. On Model 7014 Factory Installed Only. (notes 2 & 6) M = Dust-tight Gasketing (notes 4 & 5).P = Octal Plug Adapter. Can be combined only with options l1,l2. M, S, X, or Y1. (note 4).S = Dial Stops.T = Auxiliary Switch, two-step timing (notes 2 & 6).V = Transient/Surge Protection (for DC coil voltage only).W = Watertight Enclosure (note 1).X = Panelmount includes hardware and adjustment for horizontal operation (note 4)Y1 = Horizontal calibration, for horizontal operation without panelmounting (note 4).Y2 = Horizontal calibration, with Compensating Spring for vertical operation (note 4).4. Coil Voltage:AC CoilsA = 120VAC, 60 Hz.; 110VAC, 50Hz.B = 240VAC, 60 Hz.; 220VAC, 50Hz.C = 480VAC, 60 Hz.D = 550VAC, 60 Hz.E = 24VAC, 60 Hz.F = 127VAC, 50 Hz.G = 240VAC, 50Hz.H = 12VAC, 60 Hz.K = Dual voltage (combines A & B)L = Special AC coils (L1, L2, etc.)5.Timing Range:Models 7012, 7022 & 7024A = .1 to 1 sec.B = .5 to 5 sec.C = 1.5 to 15 sec.D = 5 to 50 sec.E = 20 to 200 sec.F = 1 to 10 min.H = 3 to 30 min.I = 6 to 60 min.J = 3 to 120 cyc.K = 1 to 300 sec.6.Options:A1 = Single quick-connect terminals (note 4).A2 = Double quick-connect terminals (note 4).B = Plug-in connectors (note 4).GZ = Enclosure with bottom knockouts (note 1).H2 = Hermetically sealed enclosure, 8 pin solder (notes 1 & 4).H3 = Hermetically sealed enclosure, 8 pin octal (notes 1 & 4).H4 = Hermetically sealed enclosure, 8 screw terminal block (notes 1 & 4).*H6 = Hermetically sealed enclosure, 11 pin solder (notes 1 & 4).*H7 = Hermetically sealed enclosure, 11 pin octal (notes 1 & 4).*H8 = Hermetically sealed enclosure, 11 screw terminal block (notes 1 & 4).l1 = Tamper-proof Cap, opaque black (Cannot be combined with Option X).l2 = Tamper-proof Cap, transparent (Cannot be combined with Option X).Notes:

1.Cannot be combined with B, P or X Options2.Cannot be combined with B, P or Y2 Options

3. Cannot be combined with GZ, H, l1, l2, K, W or Y1 Options4.Not Avail. on 4-Pole Models

5. Not Available with L, T or LL options.

6.Not Available on hermetically sealed units.

*Sized to accommodate one L or T Auxiliary Switch

** Not available on On-Delay, Off-Delay (Double Head) model.

†Available with letter calibrated dials only. Upper end of time range may be twice the value shown†† 120 cycles = 2 sec.

Our authorized distributors are more likely to maintain the following items in stock for immediate delivery..

7012AA7012AB7012AC7012AD7012AE7012AF7012AH7012AK7012ACL

7012BC7012NC7012PA7012PB7012PC7012PD 7012PF 7012PJ 7012PK

7012PKX7012PJX7022AA7022AB7022AC7022AD7022AE7022AF7022AH

7022AI7022AJ7022AKT7022BC7022BK7022PA7022PB7022PC7022PK

1252reference purposes only.

Dimensions are shown for

http://oneic.com/

Dimensions are in inches over(millimeters) unless otherwisespecified.

Specifications and availabilitysubject to change.

www.tycoelectronics.comTechnical support:

Refer to inside back cover.

Catalog 1308242Issued 3-03 (PDF Rev. 10-07)AGASTATOrdering options – can only be orderd as factory installed options (Dimensions, where shown, are in inches.)A1 – Single Quick-Connect Terminals

A2 – Double Quick-Connect Terminals

B – Plug-In Connectors

Use with Accessory“C” or “D” below.

GZ – Total Enclosure

With knockouts for bottomconnection.

3.16\" W x 3.84\" D x 7.63\"H

H – Hermetically Sealed EnclosureI – Tamper-Proof Cover

K – Explosion proof Enclosure

(Meets requirements forClass I, Groups C&Dlocations).

7.50\"W x 6.00\" D x 10.38\" H

L – Auxiliary SwitchLL – Auxiliary Switch

M – DustightP – Octal Plug AdapterS – Dial Stops

GasketGasket

T – Auxiliary SwitchV – Transient/Surge ProtectionW – Watertight Enclosure (NEMA-4)

4.75\" W x 4.44\" D x 9.75\" H

TransientProtectionX – Panelmount Kit

Mounting hardwareincluded.

Accessories (Not available for 7032 models)

Plug-In Receptacle (Accessory C)

Screw Terminals CatalogNo. 700137.For use with\"B\" Option

Plug-In Receptacle (Accessory D)

Quick ConnectTerminals

Catalog No. 700141.For use with \"B\"Option.

Ordering options can only be ordered as factory installed options.

Dimensions are shown forreference purposes only.

Dimensions are in inches over(millimeters) unless otherwisespecified.

Specifications and availabilitysubject to change.

www.tycoelectronics.comTechnical support: 1253Refer to inside back cover.

http://oneic.com/

分销商库存信息:

TYCO

4-1423157-42-1423157-21423165-2

2-1423162-33-1423159-11423160-1

1-1423162-51423165-31423165-4

因篇幅问题不能全部显示,请点此查看更多更全内容

Copyright © 2019- huatuo9.cn 版权所有 赣ICP备2023008801号-1

违法及侵权请联系:TEL:199 18 7713 E-MAIL:2724546146@qq.com

本站由北京市万商天勤律师事务所王兴未律师提供法律服务