承台冲切和抗剪验算
承台冲切和抗剪验算
承台冲切及抗剪验算
1、 三桩承台:
(1) 墙柱冲切验算:三桩承台上竖向荷载设计值为F=3369KN
承台抗冲切力为
N=2[()()]Ox c oy oy c ox hp t o b a h a f h βββ+++
=2[0.92(0.40.71)1(0.80.64)] 1.0214301??++?+=7179KN F<=\"\">
(2) 角桩冲切验算:桩设计反力值为N l =1110KN
承台抗冲切力为: N= 11111(2)tan 2hp t o c a f h θ
ββ+
=0.933×(2×0.9+0.4) ×1.02×0.577×1430×1=1727KN
N>N l 重切满足!
(3) 承台抗剪验算:承台承受最大剪力为V=2×1110=2220KN
承台抗冲剪力为:
V L = hs t o o f b h βα
=0.946 ×1.346×1430×2.84×1=5171KN
V L >V, 抗剪满足!
2、 四桩承台:
(1)墙柱冲切验算:四桩承台上竖向荷载设计值为F=4251KN
承台抗冲切力为
N=2[()()]Ox c oy oy c ox hp t o b a h a f h βββ+++
= 2[1.4(0.40.4) 1.86(0.80.2)] 1.0214301??++?+=8693KN F<=\"\">
(2)角桩冲切验算:桩设计反力值为N l =1110KN
承台抗冲切力为:
N= 121111[(/2)(/2)]x y y x hp t o c a c a f h βββ+++
=[0.933×(0.9+0.2/2)+1.244 ×(0.9+0.4/2)] ×1.02×1430×1=3359KN N>N l 重切满足!
(3)承台抗剪验算:承台承受最大剪力为V=2×1110=2220KN 承台抗冲剪力为:
V L = hs t o o f b h βα
=0.946 ×1.25×1430×3×1=5072KN
V L >V, 抗剪满足!
3、五桩承台:
(1)墙柱冲切验算:五桩承台上竖向荷载设计值为F=4251KN
承台抗冲切力为
N=2[()()]Ox c oy oy c ox hp t o b a h a f h βββ+++
= 2[1.4(0.40.4) 1.86(0.80.2)] 1.0214301??++?+=8693KN F<=\"\">
(2)角桩冲切验算:桩设计反力值为N l =1110KN
承台抗冲切力为:
N= 121111[(/2)(/2)]x y y x hp t o c a c a f h βββ+++
=[0.933×(0.9+0.2/2)+1.244 ×(0.9+0.4/2)] ×1.02×1430×1=3359KN N>N l 重切满足!
(3)承台抗剪验算:承台承受最大剪力为V=2×1110=2220KN 承台抗冲剪力为:
V L = hs t o o f b h βα
=0.946 ×1.25×1430×3×1=5072KN
V L >V, 抗剪满足!
4、 六桩承台:
(1)墙柱冲切验算:五桩承台上竖向荷载设计值为F=6700KN
承台抗冲切力为
N=2[()()]Ox c oy oy c ox hp t o b a h a f h βββ+++
= 2×[1.27×3.2+1.87×(0.25+0.46)] ×1.02×1430=15728KN
F<=\"\">
(2)角桩冲切验算:桩设计反力值为N l =1110KN
承台抗冲切力为:
N= 121111[(/2)(/2)]x y y x hp t o c a c a f h βββ+++
=[0.933×(0.9+0.2/2)+1.244 ×(0.9+0.4/2)] ×1.02×1430×1=3359KN N>N l 重切满足!
(3)承台抗剪验算:承台承受最大剪力为V=3×1110=3330KN
承台抗冲剪力为:
V L = hs t o o f b h βα
=0.946 ×1.25×1430×4.8×1=8116KN
V L >V, 抗剪满足!